- Mærke: Michell Instruments
Tags: SF82, Dew-Point, Transmitter, for, Compressed, Air, Michell, Instruments
SF82 Dew-Point Transmitter for Compressed Air
Simple to install and maintain, the SF82 is a fast response moisture meter measuring dew point and moisture content and is available with a range of process connections and electrical connectors. All SF82 dew-point transmitters are available with a service exchange program which reduces the cost of maintenance. Michell’s Advanced Thick Film Moisture Sensor technology based Hygrometers are calibrated to international standards and are delivered with a traceable calibration certificate.
Product Features
- Dew point or ppmV moisture content output
- Accuracy ±2 °C dew point
- Modbus RTU over RS485 digital communication 4 to 20 mA 2 wire
- Traceable 9 point calibration certificate
- Power supply 5 to 28 V DC
- Ultra fast response to moisture change
- Low cost of ownership and easy maintenance with
- sensor exchange program
- 316 stainless steel sensor and sample blocks
- 5/8” UNF, 3/4” UNF, G 1/2” process connections
- MiniDIN 43650 C, M12 electrical connectors
Applications
Dew-point measurements for:- Refrigeration dryers
- Membrane dryers
- Adsorption dryers
- Medical and surgical air
- Breathing air
- Additive manufacturing
- Plastic injection moulding
3D CAD files
Includes:- SF82 5/8 UNF
- SF82 3/4 UNF
- SF82 5/8 UNF
- SF82 3/4 UNF
- SF82 G1/2
Technical Specifications
SF82 MiniDIN 43650 C SF82 M12 Performance Specifications Measurement Range -60 °C to +60 °C dew point Accuracy ±2 °C dew point* Response Time 63% at room temperature at 1 bara
-60 °C to -20 °C dew point: 6 s
-20 °C to -60 °C dew point: 40 sRepeatability 0.5°C dew point Calibration 9 point calibration certificate traceable to national standards Electrical Specifications Output Signal User configurable over range; 4-20 mA (2 wire connection, current source) User configurable over range; 4-20 mA (2 wire connection, current source)
Modbus RTU over RS485 digital communicationsMoisture Output Dew point or moisture content Temperature Output Not available Data via Modbus RTU Analog Output Scaled Range 4-20 mA (Dew point) -60 °C to +60 °C dew point
-50 °C to +50 °C dew point
-50 °C to +30 °C dew point
-80 °C to +20 °C dew point
-20 °C to +50 °C dew point
(Non standard ranges available on request)Analog Output Scaled Range 4-20 mA (moisture content in gas) 0 to 24000 ppmv (Non standard ranges available on request) Supply Voltage 6.5 to 28 V DC 5 to 28 V DC Load Resistance Max 250 Ω @ 12 V (500 Ω @ 24 V) Current Consumption 23 mA max Analog only 23 mA max, Digital only 6 mA max Electrical Safety IEC61010-1, UL61010-1 & CAN/CSA C22.2 No. 61010 IEC61010-1, UL61010-1 & CAN/CSA C22.2 No. 61010
EN61373 Rail Rolling Stock
EN50121-3-2 Rail EMC/RFIOperating Specifications Operating Temperature -20 °C to +60 °C Compensated Temperature Range -20 °C to +50 °C Storage Temperature -40 °C to +60 °C Maximum Operating Pressure 10 MPag (100 barg) maximum Pressure Safety Rating 45 MPag (450 barg) maximum Flow Rate 1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion Mechanical Specifications Ingress Protection IP66 in accordance with BS EN 60529 (current version);
NEMA 4 ingress protection in accordance with NEMA 250 (current version)IP65 Housing Material 316 stainless steel Dimensions L = 133 mm x ø45 mm (with connector cable) L = 156 mm x ø45 mm (with connector cable)L = 133 mm x ø45 mm (with connector cable) Filter (Sensor Protection) Standard: HMWPE <10 μm Optional: 316 stainless steel sintered guard <80 μm Process Connection 5/8” 18 UNF
3/4” 16 UNF
G1/2” BSPWeight 150 g (excluding connector cable) Electrical Connections MiniDIN 43650 form C M12 5 pin (A coded) Mating Electrical Connections Mating connector supplied as standard Optional 0.8, 2, 5, 10 metre MiniDIN connector/cable available Optional 0.8 , 2, 5, 10 meter M12 A coded connector/cable available Analog Output Diagnostic Conditions (factory programmed) Sensor fault: 23 mA
Under-range dew point: mA
Over-range dew point: mANOTES * Over Compensated Temperature Range