AII-3000 Series, Palm O2

Analytical Industries’ AII-3000 series or Palm O2 are a convenient way to check oxygen levels in welding gases. These cost effective gas analyzers also measure and display the concentration of oxygen in compressed breathing air tanks intended for scuba diving, for personnel safety, O2 deficiency in confined spaces, as well as confirming the O2 levels prior to welding. These monitors use similar electrochemical galvanic fuel cell oxygen sensor that are extensively used to measure concentrations from 0% to 100% O2 in gas streams.


Product Features

  • 0-100% O2 measurement range
  • Long sensor life up to 60 months (AII-3000)
  • Battery life up to 13,000 hours of continuous use (Palm O2)
  • Integrated or remote sensors
  • Fast response time of T90 in <10 seconds


Technical Specifications
AII-3000 Palm O2 Palm CO Analyzer
Measurement Range 0-100% oxygen 0-25 ppm CO
Accuracy < ±2% of FS range under constant conditions < ±2 ppm under constant conditions
Response time T90 <10 seconds T90 <30 seconds
Sensitivity (LDL) 0.50% 0.5 ppm CO
Linearity ±1% under constant conditions
Sensor model AII-11-60 (remote sensor)
AII-11-60-HC
AII-11-75-PO2
AII-11-75-PO2-D (for diving)
GOSV-22-AF
Sensor life at 25ºC (77°F) and 1 atm 60 months in air 5°C (77°F) and 1 atmosphere G32 months in air 5°C (77°F) and 1 atmosphere 24 months in air 5°C (77°F) at 1 atmosphere
Calibration interval Prior to use and after 8 hours operation Certified span gas mixture of CO concentrations between 10-20 ppm with balance air.
Inlet pressure Ambient or 0.34-2 barg (5-30 psig) for flow through connector 800 1200 mbara (11.6-17.4 psig)
Flow rate (constant) 0.2-10 Nl/min (0.4-20 SCFH)
Gas connections 1x16 mm thread
1/4" tube for remote sensors
See accessories for additional connectors
Supplied with Dome adapter (A-3388) with optional BC adapter (A-3671)
Display 3½ digit backlit LCD 7 x 3.5cm (2.75 x 1.375"); resolution 0.1 3 digit LCD 2.8 x 1.6cm (1.1 x 0.625"); resolution 0.1 2 digit LCD 2.8 x 1.6cm (1.1 x 0.625"); resolution 1 ppm CO
Dimensions 9.1 x 14.9 x 4cm (3.6 x 5.9 x 1.6") 6.9 x 10.4 x 3.4cm (2.72" x 4.1" x 1.35")
Weight 280g (10oz) 196g (7oz)
Compensation Temperature compensated NA
Alarms User adjustable HI and LO alarms (AII-3000 M and MHC only)
Storage temperature -20°C to +60°C (-4°F to 140°F) on intermittent basis 3°C to 35°C (37.4°F to 95°F)
Operating temperature 5 to 45°C (41°F to 113°F) 0°C to 50°C (32°F to 122°F)
Power 2 AA alkaline batteries
Battery Life Up to 1200 hrs Up to 1300 hrs Up to 450 hrs of continual use
Humidity Non-condensing 0-95% RH
Warm up time None 60 Seconds
Approvals ISO 9001:2000, MDD 93/42/Annex II, ISO 13485:2003 None