Cermet II is the intelligent choice for reliable on-line
measurement of moisture in virtually any gas, across many
applications. Cermet II combines Michell’s Advanced Ceramic
Moisture Sensor and a monitor unit that can be located up
to 1200 m apart (3930 ft). While Cermet II is so simple to
use, it has the fl exibility to be applied to almost any humidity
measurement application. The instrument can display
measurement units in °C or °F dew point, ppmV, lb/mmscf or
g/m3 across the measurement range -100 to +20°C dew point
(-148 to +68°F) at pressures up to 5000 psig. The Cermet II
also can accept a pressure signal from a pressure transmitter
(optional) providing the means of active pressure compensation
for concentration units of measurement.
Product Features
- Wide measurement range, calibrated -100 to +20°C dew point (-148 to +68°F)
- ±1°C dew point measurement accuracy (±1.8°F)
- Analog and digital output
- Pressure sensor input
- Up to 4 alarm relays
- User selectable units of measure
- Easy to read display
Technical Specification
Sensor | |
Measurement Range | -100 to +20°C dew point (-148 to +68°F) |
Accuracy | ±1°C from -60 to +20°C dew point (±1.8°F, -76 to +68°F) ±2°C from -100 to -60°C dew point (±3.6°F, -148 to -76°F) |
Enclosure | Stainless steel |
Ingress Protection | NEMA 4X |
Operating Temperature | -40 to +60°C (-40 to +140°F) compensated over -20 to +40°C (-4 to +104°F) |
Storage Temperature | -40 to +165°F |
Operating Pressure | From vacuum to 5000 psig (max) |
Flow Rate | 1 to 5 l/min (2.1 to 10.5 scfh) |
Gas Velocity | 0 to 10m/sec (0 to 32.8 ft/sec) |
Process Connection | 5/8" UNF parallel thread |
Sensor Calibration | Traceable to NIST |
Analyzer | |
Measurement Units | Pressure using an optional external transducer over a range of 0 to 4000 psig. Completely user-confi gurable for any industry standard transducer with an 4-20 mA output. Automatic compensation for ppmV, lb/mmscf and g/m3 units. |
Alarm Relays | Two user adjustable isolated 10A form 'C' rated at 240VAC or 24VDC |
Outputs: Analog Digital |
4-20 mA as standard (max load 500 Ω) user confi gurable and scalable RS485 |
Power Supply | Universal 85 to 265VAC, 50/60 Hz or 95 to 370VDC |
Operating Conditions | |
Operating Temperature Monitor: Sensor: |
0 to +50°C (32 to +122°F) -20 to +50°C (-5 to +122°F) |
Ingress Protection Monitor: Sensor: |
IP54 (NEMA 12) standard (front panel only) IP66 (NEMA4) with optional cover (front panel only) IP66 (NEMA4) |