The SF52 dew-point transmitter is a simple, cost effective
sensor designed for use in harsh industrial dryer applications
where reliability and toughness are required at an economical
cost.
The SF52 is available with a choice of G1/2” and 1/2” NPT
process connections and voltage or mA outputs. A key
feature of the unit is the recessed and protected measuring
element giving an extended sensor life cycle.
Our polymer based sensor is calibrated on a high volume
traceable calibration system, providing OEM quantities of
units on short deliveries, each with a 3 point calibration
certificate.
Product Features
- Ideal for OEM dryer use
- Dew-point measurement range -40 to +60°C (-40 to +140°F)
- Fast response
- Rugged IP65 construction
- 3-Point traceable calibration certificate
- Accuracy ±2°C (±3.6°F)
- Voltage or mA outputs
Download 3D CAD file (Step) | Click Here
|
|
Technical Specifications |
| Performance |
| Measurement Range |
-40 to +60°C (-40 to +140°F) dew point |
| Accuracy |
±2°C (±3.6°F) dew point |
| Repeatability |
0.5°C (0.9°F) dew point |
| Accuracy (Absolute Humidity) |
0.4 to 3 g/m3 on value of absolute humidity |
| Stability |
<1°C (<1.8°F) / year |
| Calibration |
Traceable 3-point calibration certificate |
| Electrical Specifications |
| Output Signal |
0 to 1, 0 to 5, 0 to 10 V or 4–20 mA (3-wire) |
| Output |
Dew point, absolute humidity |
| Analog Output Scaled Range |
Standard -40 to +60°C (-40 to +140°F)
-30 to +30°C (-22 to +86°F) 0 to 200g/m3
Non-standard available upon request |
| Supply Voltage |
14 to 30 V DC (for 0 to 10 V output) 8 to 30 V DC (for 0 to 1 / 0 to 5 V / 4-20 mA output) |
| Current Consumption |
V output <9 mA mA output <29 mA |
| CE Marked |
Certified |
| Operating Specifications |
| Operating Humidity |
0-100% RH |
| Operating Temperature |
-40 to +60°C (-40 to +140°F) |
| Operating Pressure |
2 MPa (20 barg / 290 psig maximum) |
| Thermal Compensation |
Characterized over operating range temperature |
| Mechanical Specifications |
| Ingress Protection |
IP66 in accordance with standard BS EN 60529:1992 NEMA 4 in protection accordance with standard NEMA 250-2003 |
| Housing Material |
Nickel-coated brass |
| Dimensions |
L=85mm, ø24mm (maximum) |
| Filter |
HDPE front filter |
| Process Connection |
G1/2” BSP, 1/2” NPT |
| Weight |
320g (11.3oz) |
| Cable |
2m (6.6’) of halogen free TPE cable |
Diagnostic Conditions (Factory Programmed) |
| Condition | Output |
| Sensor Fault | 23 mA |
| Under-range Dew Point | 4 mA |
Over-range Dew Point | 20 mA |