LD8000

ONLINE TRACE NITROGEN AND/OR OXYGEN IN ARGON, HELIUM AND CRUDE ARGON ANALYZER

The LD8000 is an online analyzer to monitor trace N2 and/or O2 in Ar/He/Crude Argon. Different technologies combination is used to achieve the complete solution inside one compact 3U cabinet.


Product Features

  • Trace Nitrogen and Oxygen in Argon/Helium/Crude Argon
  • Compact 3U rackmount enclosure
  • Large scale measurement
  • 4-20 mA output as standard
  • LAN/Web control
  • Range Identification Relay
  • Micro-valve for very low dead volume and fast purging time
  • Low sample consumption
  • Front adjustment valve for sample bypass flow to purge the sample gas line before the analyzer
  • Optional zero gas calibration free system

Product Applications

  • Air separation unit
  • Helium cryogenic installation
  • Cryogenic truck loading station
  • Speciality gas laboratories
  • Process control
  • Argon purification plant
  • Steel Industries
  • Chemical plants
  • Welding gas control
  • Helium liquification plants
  • Gas management system
  • Semiconductor manufacturing
  • Quality control for truck fills and gas cylinders
  • Inert glove box systems
  • Universities and laboratories

Technical Specifications


LD8000
DETECTOR TYPE Plasma Emission Detector for N2 / Electrochemical cell for O2
RANGE FOR N2 0 – 1 ppm, resolution to 10 ppb
0 – 10 ppm, resolution to .1 ppm
0 – 100 ppm, resolution to 1 ppm
other range possible up to 10000 ppm configurable
RANGE FOR O2 0 – 1 ppm, resolution to 10 ppb
0 – 10 ppm, resolution to .1 ppm
0 – 100 ppm, resolution to 1 ppm
other range possible up to 25% configurable
STANDARD FEATURES Manual or autoranging (user selectable)
Microprocessor controlled
5.6'' TFT intelligent LCD module with Touch Screen
Self diagnosis system with auto-resolve alarm
4-20 mA isolated outputs
Alarm Historic
Safe calibration procedure to avoid any bad calibration
Digital outputs for remote monitoring: (all dry relay contacts)
- System status (1 output)
- Range in use (3 outputs per impurity)
- Calibration in use (1 output)
OPTIONS Internal sampling system for zero, span and sample
Serial port: RS-232 / 422 / 485 / profibus
2 alarm outputs (use programmable set point)
Zero calibration gas free system
GAS CONNECTIONS Sample: 1/8'' compression fittings
Vent: 1/8'' compression fitting
CALIBRATION GAS Zero: LDP1000 purified gas (getter)
Span: 8.0 to 9.5 ppm N2 and O2 (application dependant)
SAMPLE FLOW REQUIREMENTS 75 to 200 sccm
RECOMMENDED MAXIMUM OPERATING PRESSURE 30 PSIG (206 kPAG)
RECOMMENDED MINIMUM OPERATING PRESSURE 4 PSIG (28 kPAG) optional 1 PSIG (7 kPAG)
OPERATING TEMPERATURE 10 °C to 45 °C
SUPLLY 115 VAC, 50 - 60 Hz or 220 VAC, 50 - 60 Hz
ACCURACY Better then ± 1% full scale
DRIFT < ± 1%
RESPONSE TIME T90 < 10 seconds
O2 SENSOR LIFE 15-21 months (depending O2 concentration level exposition)
WEIGHT 29 lbs (13 kg)

CERTIFICATION

CE: In compliance with EMC directive 2004/108/EC, EN 61000-6-2:2005 for immunity & EN 61000-6-4:2007 for emissions.

Download the complete specification and technical data sheet (2,54 Mo)