- Brand: Michell Instruments
Tags: Condumax, On-Line, Hydrocarbon, Dew-Point, Analyzer, Michell, Instruments
Condumax II On-Line is a fully self-contained hydrocarbon dew
point analyzer, using the proven "Dark Spot" hydrocarbon dew point
measurement principle from the highly successful Condumax instrument.
Combining a hydrocarbon dew point cell and water dew point measurement
in the same compact and lightweight EExd enclosure, Condumax II On-Line
requires nothing more than mains power to operate.
Product Features
- Fully automatic on-line analysis
- Objective, highly repeatable measurements
- 0.5°C hydrocarbon dew-point accuracy
- Fundamental chilled mirror principle
- Patented detection technique
- Self-cleaning
- No purge or cooling gas required
- Optional water dew-point analysis
- Modbus RTU
- IECEx, ATEX, CCSAUS and GOST Ex certifications
Hydrocarbon Dew-Point Measurement | |
Measuring Technique | Dark SpotTM fixed sample analysis. Direct photo-detection of hydrocarbon condensate at hydrocarbon dew-point temperature |
Sensor Cooling | Automatic via 3-stage Peltier effect electronic cooler under adaptive control |
Maximum Range | Up to Δ -55K measurement depression from Main Unit operating temperature |
Accuracy | ±0.5°C hydrocarbon dew point (single and multiple condensible component analysis) |
Sample Flow | 0.03m³/hr (0.5 Nl/min) - alarm standard |
Measurement Frequency | 6 cycles/hour (recommended) 12 cycles/hour (maximum) |
Operating Pressure | Max. 100 barg (1450 psig) |
Water Dew-Point Measurement (Optional) | |
Measuring Technique | Michell Ceramic Moisture Sensor |
Units - Moisture content | °C and °F water dew point; lb/MMscf; mg/m3, ppmV |
Resolution | 0.1°C, 0.1°F |
Range | Calibrated from -100 to +20°C dew point |
Accuracy | ±1°C from -59 to +20°C dew point
±2°C from -100 to -60°C dew point |
Sample Flow | 0.06 to 0.3 m3/hr (1 to 5 Nl/min) alarm standard |
Temperature Coefficient | Algorithm compensation (-20 to +50°C) |
Operating Pressure | Max. 138 barg (2000 psig) |
Pressure Measurement Hydrocarbon Dew-Point Analysis Pressure Optional Water Dew-Point Process Pressure |
|
Units | MPa, barg, psig |
Resolution | 0.1 MPa and barg, 1 psig |
Range | HC dew point: 0 to 100 barg W dew point: 0 to 200 barg |
Accuracy | ±0.25% FS |
Hydrocarbon Dew-Point Analyzer | |
Resolution | Hydrocarbon and water dew point: 0.1°C |
Sample Gas Supply | Natural gas up to 100 barg, pressure regulated in sampling system |
Enclosure | EExd cast enclosure with removable glass window viewing port. Internally heated for condensation protection |
Sample Gas Connections | 1/8” NPT (ATEX / IECEx) or 1/4” NPT (CSA) female ports for both hydrocarbon and water dew-point channels; Sampling system: 6mm OD or 1/4” OD |
Operating Environment | Indoors/Outdoors -20 to +50°C; Max 95% RH |
Power Supply | 90 to 260 V AC, 50/60 Hz, 125 W Main Unit 300 W c/w Sampling System (indoor) 400 W c/w Sampling system (outdoor) |
Weight | 22.5kg Main Unit 60kg (approx) c/w Sampling System (indoor) 75kg (approx) c/w Sampling system (outdoor) |
Integrated Display/Keyboard | Touch screen with vacuum fluorescent display |
Outputs | Modbus RTU, RS485 @ 9600 baud rate Two 4-20 mA linear (non-isolated) outputs, user-configurable for any combination of dew-point or pressure parameters |
Alarms | Process and analyzer status via software register and display annotation Integrated low flow alarms for each sample flow Analyzer status fault flag 23 mA on mA Output 1 |
Certification | |
Hazardous Area Certification | ATEX: II 2G Ex d IIB + H2 Gb (-40°C to +44°C) T6 (-40°C to +59°C) T5 IECEx: Ex d IIB + H2 Gb (-40°C to +44°C) T6 (-40°C to +59°C) T5 cCSAus: Class I, Division 1, Groups B, C and D, T6 (Tamb= -40°C to +44°C) T5 (Tamb= -40°C to +59°C) |
Pattern Approval | GOST-R, GOST-K, GOST-T |
|